ASD1000 FSX – Diode Array Solid State polychromator based detector

MS AAS Plus ADS1000 FSX is fully automated PC Controlled atomic absorption spectrophotometer with flame system.

The system uses state-of-art imaging sensor to perform analysis simultaneously like an OES-Multi-Elemental Analysis. This allows the system to resolve all wavelengths at once unlike conventional system which uses monochromator and are bound to resolve one a specific wavelength. Therefore, the number of HCL lamp does not matter, as to fully utilize the capability of instrument, multi-element lamp is used. The system can perform analyses upto 8 element simultaneously.

The system compromises of automatic independent HCL turret with automatic variable spectral bandpass.

The system uses state-of-art, ultra-fast lamp modulation up to 1024 Hertz coupled with imaging sensor with internal reference beam for double beam operation and uses two-line background correction to achieve extreme stable and reproducible results.

General Specifications

  • Multi Element analysis in real time
  • 4 analysis (Zn,Mn,Fe,Cu) in 3 seconds
  • Zero moving parts for superior stability
  • USB connectivity
  • Reference beam available
  • Ultra fast 1024 Hz modulation
  • ABS range from -0.3 to 3.5 ABS
  • Automatic slit and gain control
  • Automatic gas box with real time sensing for Fuel, Oxidant, Nebulizer, Water Trap, Bung

Optics

• Czerny Turner configuration with stray light correction
• Automatic wavelength calibration
• Original holographic grating blazed at 230.0nm
• 1200lines/mm as standard
• 4 analysis (Zn,Mn,Fe,Cu) in 3 seconds
• Zero moving parts for superior stability
• USB connectivity
• Reference beam available
• Ultra fast 1024 Hz modulation
• ABS range from -0.3 to 3.5 ABS
• Automatic slit and gain control

Atomizer & Flame System

  • PTFE inert atomizer with 100mm burner for Air-Acetylene flame
  • Software controlled Fuel and Oxidant operation and monitoring
  • Automatic safe shutdown on loss of pressure, nebulizer, water trap, bung
  • Display of status of all monitoring in software and on instrument panel
  • Flame cut off provided through software, hardware button and sensing signals
  • Optional software controlled movement in 3 axis
  • Error history saving and acknowledgement
  • Variable Nebulizer with flow control from 0.1 to 10ml/minute

Operating Software

  • ·Automatic initialization and self-diagnostics on startup
  • Powerful analysis setup with adjustment of replicates, integration time and read delay
  • CFR21 part 11 complaint software with database support to capture all events and results generated by the software
  • Gasbox control via simple interface
  • Easy calibration of multi standards

Specifications