MS AAS Plus ADS1000 FSX is fully automated PC Controlled atomic absorption spectrophotometer with flame system.
The system uses state-of-art imaging sensor to perform analysis simultaneously like an OES-Multi-Elemental Analysis. This allows the system to resolve all wavelengths at once unlike conventional system which uses monochromator and are bound to resolve one a specific wavelength. Therefore, the number of HCL lamp does not matter, as to fully utilize the capability of instrument, multi-element lamp is used. The system can perform analyses upto 8 element simultaneously.
The system compromises of automatic independent HCL turret with automatic variable spectral bandpass.
The system uses state-of-art, ultra-fast lamp modulation up to 1024 Hertz coupled with imaging sensor with internal reference beam for double beam operation and uses two-line background correction to achieve extreme stable and reproducible results.
General Specifications
- Multi Element analysis in real time
- 4 analysis (Zn,Mn,Fe,Cu) in 3 seconds
- Zero moving parts for superior stability
- USB connectivity
- Reference beam available
- Ultra fast 1024 Hz modulation
- ABS range from -0.3 to 3.5 ABS
- Automatic slit and gain control
- Automatic gas box with real time sensing for Fuel, Oxidant, Nebulizer, Water Trap, Bung
Optics
• Czerny Turner configuration with stray light correction • Automatic wavelength calibration • Original holographic grating blazed at 230.0nm • 1200lines/mm as standard • 4 analysis (Zn,Mn,Fe,Cu) in 3 seconds • Zero moving parts for superior stability • USB connectivity • Reference beam available • Ultra fast 1024 Hz modulation • ABS range from -0.3 to 3.5 ABS • Automatic slit and gain control |
Atomizer & Flame System
- PTFE inert atomizer with 100mm burner for Air-Acetylene flame
- Software controlled Fuel and Oxidant operation and monitoring
- Automatic safe shutdown on loss of pressure, nebulizer, water trap, bung
- Display of status of all monitoring in software and on instrument panel
- Flame cut off provided through software, hardware button and sensing signals
- Optional software controlled movement in 3 axis
- Error history saving and acknowledgement
- Variable Nebulizer with flow control from 0.1 to 10ml/minute
Operating Software
- ·Automatic initialization and self-diagnostics on startup
- Powerful analysis setup with adjustment of replicates, integration time and read delay
- CFR21 part 11 complaint software with database support to capture all events and results generated by the software
- Gasbox control via simple interface
- Easy calibration of multi standards