1200V – Visible Spectrophotometer

1200V is a portable, rugged and full functional spectrometer which can identify and quantify compounds based on molecular absorption.

The portable nature of the system, coupled with no mechanical movements results into an extremely rugged system. The device uses ultra-fast CCD/CMOS array element which captures the entire spectrum in less than 0.1 seconds.

The sensitivity of the unit is at par or exceeding that of benchtop based spectrometers.

  • Rugged with no moving components
  • User selectable integration time
  • Built in Windows 10 with high resolution LCD touch screen display
  • Industry proven design
  • 340-1000nm spectral range
  • 1nm resolution
  • Powerful SDK
  • Self-diagnostic
  • External calibration available to user
  • CFR21 part 11 complaint software with database support to capture all events and results generated by the software
AlphaCapture(c)Design
The Diode Array Based Spectrophotometer based polychromator is based on our ALPHACAPTURE platform.
The above diagram shows the internals of the system. The light enters through a slit and is collected by a collimating mirror, received by the Grating and focused by a focusing mirror over the detector. Usage of special metal alloy with lowest thermal expansion coefficient allows stable results in huge temperature ranges

With the power of Scanalyse software, the post processing of data with mathematical operation is a breeze. Check out a scan of visible spectrum of SRM. The peaks wavelenghts and ABS matches with the certified values.

This complete scan was generated within 2 seconds including blanking and physically placing the SRM into the instrument!

Power of Scanalyse
Wavelength Range340.0 – 1100.0nmStray Light>3.6A @ 340nm
Photometric SystemSingle / Split BeamPhotometric Readability-3.0A to 3.0A
Grating1200 lines/mmTransmittance Range0% to 400%
Spectral Bandwidth1.0nmABS Repeatability0.005
DetectorDiode array with 3648 ElementLight SourceTungsten Halogen
Wavelength Increment0.1nmSoftwareScanalyse(r) with CFR21 compliance
Data InterfaceWifi, USB, WirelessTouch screen configuration8″ with Colour touchscreen built in Windows 10
Noise Level0.001 AWeight700g
Wavelength Accuracy0.1nm @ 656.1nmEnvironmental RequirementsTemperature = 10c to 40c
Humidity = 0% to 80%
Wavelength Repeatability0.3nmPower Requirements100V – 290V AC
12V DC @ 2.5 A
Full spectrum scan time0.1 SecondsDimensions25.0 x 18.0 x 10.0 cm
Photometric Accuracy0.002 A @ 0.5 A
Baseline Stability0.001 A/h