The Motras Scientific 1600UV is a portable, rugged and full functional UV Visible CCD based spectrometer which can identify and quantify compounds based on molecular absorption.
The portable nature of the system, coupled with no mechanical movements results into an extremely rugged system. The device uses ultra-fast CCD array element which captures the entire spectrum in less than 0.1 seconds.
The CCD based polychromator is based on our ALPHACAPTURE platform.
The above diagram shows the internals of the system. The light enters through a slit and is collected by a collimating mirror, received by the Grating and focused by a focusing mirror over the detector. Usage of special metal alloy with lowest thermal expansion coefficient allows stable results in huge temperature ranges
With the power of Scanalyse software, the post processing of data with mathematical operation is a breeze. Check out a scan of visible spectrum of SRM. The peaks wavelenghts and ABS matches with the certified values.
This complete scan was generated within 2 seconds including blanking and physically placing the SRM into the instrument!
- Rugged with no moving components
- User selectable integration time
- Built in Windows 10 with high resolution LCD touch screen display
- Industry proven design
- 190-1000nm spectral range
- 1nm resolution
- Powerful SDK
- Self-diagnostic
- External calibration available to user
- CFR21 part 11 complaint software with database support to capture all events and results generated by the software
Parameter | Details |
---|---|
Wavelength range | 190 to 1100 nm |
Photometric system | CCD based realtime ABS scan for all wavelengths simultaneously |
Grating | 600/1200 lines/mm |
Spectral Bandwidth | Fixed at 1.0nm |
Detector | Linear CCD Array |
Wavelength Increment | 0.1nm |
Data Interface Speed | Up to 2Mbps |
Noise Level | 0.0012 ABS |
Wavelength Accuracy | 1.0nm@656.1nm |
2.0nm overall | |
Wavelength Repeatability | ±0.3nm |
Single spectrum scan time | 0.1 second |
Photometric accuracy | ±0.002 Abs at 0.5 Abs |
±0.004 Abs at 1.0 Abs | |
±0.006 Abs at 2.0 Abs | |
Baseline stability | Less than 0.001 Abs/Hr |
Stray Light | Less than 0.022% at 340 nm (NaNO2) |
Photometric readability range | Absorbance: -4.00 to 4.00 Abs |
Transmittance: 0% to 400% | |
Dimensions | 410.0×390.0x225.0mm |
Optical Interface | Direct or SP/APC or other standard optical fiber based connector as per end use |
Light source | Plug- in pre-aligned Tungsten Halogen lamp and Deuterium Lamp |
Output device | Inbuilt with Windows 10 high resolution touchscreen LCD |
Software | Scanalyse® software (Microsoft Windows 7 and above) CFR-21 compliance |
Data Output | Wifi, Bluetooth, Ethernet |
Environmental requirements | Temperature: 15C to38C |
Humidity: 30% to 80% | |
Power Requirement | AC 120v – 300v@50Hz, 40VA |