MS AAS Plus is fully automated and PC controlled atomic absorption spectrophotometer with flame & hydride system. The system compromises of automatic 10 lamp (independent power supply) HCL turret and automatic variable spectral bandpass.
The system uses state-of-art, ultra-fast lamp modulation up to 1024 Hertz coupled with Hamamatsu Photomultiplier tube, true double beam optics and Deuterium lamp background correction results into extreme stable and reproducible results. The system has integrated fibre optics light transmission double beam optics.
- Real Time true double beam spectrophotometer with wavelength range from 175.0 to 900.0 nm with reading up to 3.5 ABS
- Sensitivity > 0.9 ABS for 5.0 mg/L copper solution with RSD <0.5%
- Ultra-fast modulation up to 1024 Hz and 512 Hz for HCL and D2 background correction
- Automatic EHT optimization & selection
- PTEF inert atomizer for both flame and VGA; accommodating titanium 100 mm Air-Acetylene burner & 50 mm Nitrous Oxide – Acetylene burner
- Inbuilt dedicated 10 channel HCL Lamp supply
- CFR21 part 11 complaint software with database support to capture all events and results generated by the software
Parameter | Details |
---|---|
Wavelength range | 175 to 900 nm |
Focal Length | 250.0/300.0/330.0 mm |
Photometric system | Double beam optics with fibre optics light transmission |
Monochromator Configuration | Littrow / Ebert-Fastie / Czerny-Turner as per requirement |
Grating | 1800 lines/mm blazed at 236.0 nm |
Spectral Bandwidth | Continuously variable spectral bandwidth from 0.1 nm to 2.5 nm |
Detector | Photo Multipler Tube / CMOS sourced from Hamamatsu Photonics |
HCL Powersupply | Independent 10 channel supply |
Output device | USB through PC |
Optional Standalone controller with WiFi, Ethernet, Bluetooth | |
Gas Box System | Fully Automatic gas box with safety interlocks and software controlled automatic oxidant and fuel adjustment |
Optional Manual interlocked gas control with oxidant and flow meters with display. | |
Optional Accessories | VGA Hydride System |
Auto Sampler | |
Software | Windows based powerful analysis software |
Lamp current, spectral bandwidth, oxidant selection pre-programmed | |
CFR21 part 11 complaint software with database support to capture all events and results generated by the software | |
Large LCD type display shows all critical information simultaneously | |
Provision to digitally sign pdf document using secured token | |
Organization setup with users and roles based functionality | |
Client-Server architecture to enable audit trail and results capturing on server | |
Environmental and Electrical | Dimensions : 865.0mm (L) x 525.0mm (W) x 410.0mm (H) |
Dry Weight: 65 KG | |
Power Requirement: AC 230 ± 10% with proper ground earth. | |
Temperature Range: 15c – 40c | |
Humidity: 0% – 80% |